SUN2000-12/15/17/20/25K-MB0

Smart Energy Controller

SUN2000-12/15/17/20/25K-MB0

specs
specs
specs
specs
specs

Smart Energy Controller

Technical Specification1 SUN2000-12K-MB0 SUN2000-15K-MB0 SUN2000-17K-MB0 SUN2000-20K-MB0 SUN2000-25K-MB0
Efficiency specs-icon
Max. efficiency 98.4% 98.4% 98.4% 98.4% 98.4%
European weighted efficiency 97.9% 98.0% 98.1% 98.1% 98.2%
DC Input specs-icon
Recommended max. PV power 18,000 Wp 22,500 Wp 22,500 Wp 30,000 Wp 37,500 Wp
Max. input voltage2 1,100 V
Max. input current per MPPT 30 A (two strings) / 20 A (single string)
Max. short-circuit current 40 A
Start-up voltage 200 V
MPPT operating voltage range3 200 V ~ 1,000 V
Full-load MPPT voltage range 370 V ~ 800 V 410 V ~ 800 V 440 V ~ 800 V 480 V ~ 800 V 530 V ~ 800 V
Rated input voltage 600 V
Max. number of inputs 4
Number of MPP trackers 2
Smart String Energy Storage System Terminal specs-icon
Compatible Smart String ESS LUNA2000-5/10/15-S0
Number of terminals 2
Max. charging power 21 kW (Single string) / 25 kW (Two strings)
Max. discharge power 13.2 kW 16.5 kW 18.7 kW 22.0 kW 25.0 kW
Max. operating current 26.25 A (per string)
Operating voltage range 600 V ~ 980 V
Output specs-icon
Rated output power 12,000 W 15,000 W 17,000 W 20,000 W 25,000 W
Max. apparent power 13,200 VA 16,500 VA 18,700 VA 22,000 VA 27,500 VA
Max. active power (cosφ = 1) 13,200 W 16,500 W 18,700 W 22,000 W 27,500 W
Rated output voltage 220 Vac / 380 Vac, 230 Vac / 400 Vac, 240 Vac / 415 Vac; 3 W / N + PE
Rated output current 18.2 A / 380 Vac
17.3 A / 400 Vac
16.7 A / 415 Vac
22.8 A / 380 Vac
21.7 A / 400 Vac
20.9 A / 415 Vac
25.8 A / 380 Vac
24.5 A / 400 Vac
23.7 A / 415 Vac
30.4 A / 380 Vac
28.9 A / 400 Vac
27.8 A / 415 Vac
38.0 A / 380 Vac
36.1 A / 400 Vac
34.8 A / 415 Vac
Max. output current 20.2 A / 380 Vac
19.1 A / 400 Vac
18.5 A / 415 Vac
25.2 A / 380 Vac
23.9 A / 400 Vac
23.1 A / 415 Vac
28.6 A / 380 Vac
27.1 A / 400 Vac
26.1 A / 415 Vac
33.6 A / 380 Vac
31.9 A / 400 Vac
30.8 A / 415 Vac
42.0 A / 380 Vac
39.9 A / 400 Vac
38.5 A / 415 Vac
Rated AC grid frequency 50 Hz / 60 Hz
Adjustable power factor 0.8 leading ... 0.8 lagging
Max. total harmonic distortion ≤ 3%
Feature & Protection specs-icon
Overvoltage category PV II / AC III
Input-side disconnection device Yes
Anti-islanding protection Yes
AC over-current protection Yes
DC reverse-polarity protection Yes
DC surge protection TYPE II
AC surge protection Yes, compatible with TYPE II protection class according to EN/IEC 61643-11
DC insulation resistance detection Yes
Residual current monitoring unit Yes
Arc fault protection Yes
General Data specs-icon
Operating temperature range -25 °C ~ +60 °C (-13 °F ~ 140 °F)
Relative humidity 0% RH ~ 100% RH
Max. operating altitude 4,000 m (13,123 ft.) (Derating above 2,000 m)
Cooling Smart air cooling
Display LED indicators, Integrated WLAN + FusionSolar APP
Communication RS485; WLAN / Ethernet via Smart Dongle-WLAN-FE (Optional)
4G / 3G / 2G via Smart Dongle-4G (Optional); EMMA (Optional; available from 30/11/2023)
Weight 21 kg
Dimensions (W x H x D) 546 x 460 x 228 mm (21.5 x 18.1 x 9.0 inch)
Protection level IP66
Max. number of paralleled unit
(with Smart String ESS)
3
Optimizer Compatibility specs-icon
Compatible optimizer SUN2000-450W-P2, SUN2000-600W-P, MERC-1100W-P, MERC-1300W-P
Standards Compliance (More Available Upon Request) specs-icon
Certificates EN/IEC62109-1, EN/IEC62109-2
Grid connection standards IEC61727, IEC62116, IEC61683, EN50530, ABNT NBR 16149/16150, MEA/PEA, G99, IRR-DCC-MV/IRR-TIC, Philippine Grid Code Resolution No. 07, NRS 097-2-1, EN50549-1, VDE4105, UTE15-712-1/VFR 2019, UNE217002, NTS631, RD244(UNE217001), PPDS, ROGA, TOR Erzeuger, CEI 0-21:2020-12 V1, CEI-016, C10/C11, EN50549-2, VDE4110

*1 For Thailand, only SUN2000-12K-MB0 & SUN2000-15K-MB0 & SUN2000-20K-MB0 are available.

*2 The maximum input voltage is the upper limit of the DC voltage. Any higher input DC voltage would probably damage inverter.

*3 Any DC input voltage beyond the operating voltage range may result in inverter improper operating.



Disclaimer: the preceding values are measured by an internal laboratory of Huawei in a specific environment. The actual values may vary with products, software versions, usage conditions, and environmental factors.