Technical Specification
SUN2000-450W-P2
SUN2000-600W-P
Input
arrow
Rated input DC power1
450 W
600 W
Absolute max. input voltage
80 V
MPPT operating voltage range
10 - 80 V
Max. short-circuit current (Isc)
14.5 A
Max. efficiency
99.5%
Weighted efficiency
99.0%
Overvoltage category
||
Output
arrow
Max. output voltage
80 V
Max. output current
15 A
Output bypass2
Yes
Output voltage during standby3
0 V
Output impedanceduring standby
1 kΩ ± 10%
Communication
arrow
Communication protocol
MBUS
Standards Compliance
arrow
Safety
IEC62109-1 (class II safety)
RoHS
Yes
Fire safety
VDE-AR-E 2100-712:2018-12
General Specifications
arrow
Dimensions (W x H x D)
75 mm x 140 mm x 28 mm (3.0 in. x 5.5 in. x 1.1 in.)
Weight (including cables)
0.6 kg (1.3 lb.)
Installation part (optional)
Frame mounting bracket / T-shaped bolt4
Input connector
Staubli MC4
Input wire length
0.15 m (0.49 ft.)
Output connector
Staubli MC4
Output wire length
1.3 m (4.3 ft.)
Operating temperature / humidity range
–40 °C to +85 °C5 / 0% - 100%
IP rating
IP68

*1 The maximum power of PV module at STC shall NOT exceed the "Rated Input DC Power" of the power optimizer. PV modules with up to +5% power tolerance are allowed.

*2 Any power optimizer, which is connected to an operating inverterin a PV string, will be bypassed when it fails.

*3 Once the power optimizer stops working, its output voltage is reduced to 0 V.

*4 It is for PV module frame/extruded aluminum profile racking system installation.

*5 When the operating temperature of the SUN2000-450W-P2/600W-P reaches 70 °C to 85 °C, it may shut down due to over-temperature protection and report an over-temperature alarm. After the temperature decreases, it can automatically resume working without causing any damage.