SUN2000-12-15-17-20-25K-MB0 Specs | Solar Inverter Three-phase Specs | Huawei FusionSolar

SUN2000-12/15/17/20/25K-MB0

Smart Energy Controller

SUN2000-12/15/17/20/25K-MB0

SUN2000-12/15/17/20/25K-MB0
SUN2000-12/15/17/20/25K-MB0
SUN2000-12/15/17/20/25K-MB0
SUN2000-12/15/17/20/25K-MB0
SUN2000-12/15/17/20/25K-MB0
Technical Specification1
SUN2000-12K-MB0
SUN2000-15K-MB0
SUN2000-17K-MB0
SUN2000-20K-MB0
SUN2000-25K-MB0
Efficiency
arrow
Max. efficiency
98.4%
98.4%
98.4%
98.4%
98.4%
European weighted efficiency
97.9%
98.0%
98.1%
98.1%
98.2%
DC Input
arrow
Recommended max. PV power
18,000 Wp
22,500 Wp
22,500 Wp
30,000 Wp
37,500 Wp
Max. input voltage2
1100 V
Max. short-circuit current
40 A
Start-up voltage
200 V
Max. input current per MPPT
30 A (two strings) / 20 A (single string)
MPPT operating voltage range3
200 V - 1000 V
Full-load MPPT voltage range
370 V - 800 V
410 V - 800 V
440 V - 800 V
480 V - 800 V
530 V - 800 V
Rated input voltage
600 V
Max. number of inputs
4
Number of MPP trackers
2
Smart String Energy Storage System Terminal
arrow
Compatible Smart String ESS
LUNA2000-5/10/15-S0, LUNA2000-7/14/21-S1
Number of terminals
2
Max. charging power
21 kW (Single string) / 25 kW (Two strings)
Max. discharge power
13.2 kW
16.5 kW
18.7 kW
22.0 kW
25.0 kW
Max. operating current
26.25 A (per string)
Operating voltage range
600 V ~ 980 V
Output
arrow
Rated output power
12,000 W
15,000 W
17,000 W
20,000 W
25,000 W
Max. apparent power
13,200 VA
16,500 VA
18,700 VA
22,000 VA
27,500 VA
Max. active power (cosφ = 1)
13,200 W
16,500 W
18,700 W
22,000 W
27,500 W
Rated output voltage
220 V AC / 380 V AC, 230 V AC / 400 Vac, 240 V AC / 415 V AC; 3 W/N + PE
Rated output current
18.2 A / 380 V AC
17.3 A / 400 V AC
16.7 A / 415 V AC
22.8 A / 380 V AC
21.7 A / 400 V AC
20.9 A / 415 V AC
25.8 A / 380 V AC
24.5 A / 400 V AC
23.7 A / 415 V AC
30.4 A / 380 V AC
28.9 A / 400 V AC
27.8 A / 415 V AC
38.0 A / 380 V AC
36.1 A / 400 V AC
34.8 A / 415 V AC
Max. output current
20.2 A / 380 V AC
19.1 A / 400 V AC
18.5 A / 415 V AC
25.2 A / 380 V AC
23.9 A / 400 V AC
23.1 A / 415 V AC
28.6 A / 380 V AC
27.1 A / 400 V AC
26.1 A / 415 V AC
33.6 A / 380 V AC
31.9 A / 400 V AC
30.8 A / 415 V AC
42.0 A / 380 V AC
39.9 A / 400 V AC
38.5 A / 415 V AC
Rated AC grid frequency
50 Hz / 60 Hz
Adjustable power factor
0.8 leading ... 0.8 lagging
Max. total harmonic distortion
≤ 3%
Feature & Protection
arrow
Overvoltage category
PV II / AC III
Input-side disconnection device
Yes
Anti-islanding protection
Yes
AC over-current protection
Yes
DC reverse-polarity protection
Yes
DC surge protection
TYPE II
AC surge protection
Yes, compatible with TYPE II protection class according to EN/IEC 61643-11
DC insulation resistance detection
Yes
Residual current monitoring unit
Yes
Arc fault protection
Yes
General Specification
arrow
Operating temperature range
-25 °C to +60 °C (-13 °F to 140 °F)
Relative humidity
0% RH - 100% RH
Max. operating altitude
4000 m (13,123 ft.) (Derated above 2000 m)
Cooling
Smart air cooling
Display
LED indicators, Integrated WLAN + FusionSolar APP
Communication
RS485; WLAN/Ethernet via Smart Dongle-WLAN-FE (Optional)
4G/3G/2G via Smart Dongle-4G (Optional); EMMA (Optional)
Weight
21 kg
Dimensions (W x H x D)
546 mm x 460 mm x 228 mm (21.5 x 18.1 x 9.0 inch)
Protection level
IP66
Max. number of paralleled unit (with Smart String ESS)
3
Optimizer Compatibility
arrow
Compatible optimizer
SUN2000-450W-P2, SUN2000-600W-P, MERC-1100W-P, MERC-1300W-P
Standards Compliance (More Available Upon Request)
arrow
Certificates
EN/IEC62109-1, EN/IEC62109-2
Grid connection standards
IEC61727, IEC62116, IEC61683, EN50530, ABNT NBR 16149/16150, MEA/PEA, G99, IRR-DCC-MV/IRR-TIC, Philippine Grid Code Resolution No. 07, NRS 097-2-1, EN50549-1, VDE4105, UTE15-712-1/VFR 2019, UNE217002, NTS631, RD244(UNE217001), PPDS, ROGA, TOR Erzeuger, CEI 0-21:2020-12 V1, CEI-016, C10/C11, EN50549-2, VDE4110

*1 For Thailand, only SUN2000-12K-MB0 & SUN2000-15K-MB0 & SUN2000-20K-MB0 are available.

*2 The maximum input voltage is the upper limit of the DC voltage. Any higher input DC voltage would probably damage the inverter.

*3 Any DC input voltage beyond the operating voltage range may result in inverter malfunction.

*4 Disclaimer: The preceding values are measured by an internal laboratory of Huawei in a specific environment. The actual values may vary with products, software versions, usage conditions, and environmental factors.