Smart Module Optimizer Specs_Power Optimizer Specs | Huawei FusionSolar

MERC-1100/1300W-P

Smart Module Controller

MERC-1100/1300W-P

MERC-1100/1300W-P
Technical Specification
MERC-1100W-P
MERC-1300W-P
Input
arrow
Rated input DC power1
1100 W
1300 W
Absolute max. input voltage
125 V
MPPT operating voltage range
12.5 - 105 V
Max. short-circuit current (Isc)
20 A
Max. efficiency
99.5%
Weighted efficiency
99.0%
Overvoltage category
||
Output
arrow
Max. output voltage
80 V
Max. output current
22 A
Output bypass2
Yes
Safety output voltage3
1 V
Standards Compliance
arrow
Safety
IEC62109-1 (class II safety)
RoHS
Yes
General Specification
arrow
Dimensions (W x H x D)
149 mm x 104 mm x 48.8 mm (5.9 in. x 4.1 in. x 1.9 in.)
Weight (including wires)
1.0 kg (2.2 lb.)
Installation kit (optional)
PV Module Frame Plate/T-shaped Bolt4
Input connector
Staubli MC4
Input wire length
0.1 m (+/-) (short-input-cable version)5
Output connector
Staubli MC4
Output wire length
0.1 m (+), 5.1 m (-) (short-input-cable version)5
Operating temperature
–40 °C to +85 °C6
Relative humidity
0% - 100%
IP rating
IP68
Compatible inverters
SUN2000-12-25K-MB0, SUN2000-12-25KTL-M5, SUN2000-30-40KTL-M3, SUN2000-50KTL-M3, SUN5000-150K-MG0
PV System Design7 / 8 / 9
arrow
PV System Design7 / 8 / 9
SUN2000- 12~25K-MB0
SUN2000- 12~25KTL-M5
SUN2000- 30~40KTL-M3
SUN2000- 50KTL-M3
SUN5000-150K-MG0
Min. string length (power optimizers)
8
8
8
8
12
Max. string length (power optimizers)
25
25
25
20
20
Max. DC power per string
20,000 W
20,000 W
20,000 W
20,000 W
20,000 W

*1 The maimum power of PV module at STC shall NOT exceed the “Rated input DC power” of MERC-1100/1300W-P. PV Modules with up to ±10% power tolerance are allowed.

*2 Any power optimizer, which is connected to an operating inverter in a PV string, will be bypassed when it fails.

*3 When the MERC-1100/1300W-P is disconnected from inverter or when the inverter is off, its output voltage will become 1 V

*4 It is for PV module frame/extruded aluminum profile racking system installation.

*5 Pay attention to the PV module wire length. To match PV modules with a split junction box and short output wire, the long-input-cable version (input wire: 1.3 m (+/-); output wire: 0.1m (+)/2.9m (-)) of MERC-1100/1300W-P is available upon request.

*6 When the operating temperature of the MERC-1100/1300W-P reaches 70 °C to 85 °C, it may shut down due to over-temperature protection and report an over-temperature alarm. After the temperature decreases, it can automatically resume working without causing any damage.

*7 Each PV module under the same inverter must be equipped with a MERC-1100/1300W-P.

*8 SUN2000-450W-P2/600W-P and MERC-1100/1300W-P can NOT be used in mixture under the same Smart Energy/PV Controller

*9 It is recommended that strings under the same inverter have an equal capacity. If this is not feasible, the capacity difference between strings under the same inverter must not exceed 2 kW. Otherwise, the energy yield will be reduced.

*10 Disclaimer: The preceding values are measured by an internal laboratory of Huawei in a specific environment. The actual values may vary with products, software versions, usage conditions, and environmental factors.