Smart Module Controller

MERC-1100/1300W-P

Smart Module Controller

Smart Module Controller

Technical Specification MERC-1100W-P MERC-1300W-P
Input specs-icon
Rated input DC power1 1100 W 1300 W
Max. input voltage 125 V
MPPT operating voltage range 12.5 - 105 V
Max. short-circuit current (Isc) 20 A
Max. efficiency 99.5%
Weighted efficiency 99.0%
Overvoltage category ||
Output specs-icon
Max. output voltage 80 V
Max. output current 22 A
Output bypass2 Yes
Shutdown output voltage per optimizer3 1 V
Standards Compliance specs-icon
Safety IEC62109-1 (class II safety)
RoHS Yes
General Data specs-icon
Dimension (W x H x D) 149 mm x 104 mm x 49 mm (5.9 in. x 4.1 in. x 1.9 in.)
Weight (including cables) 1.0 kg (2.2 lb.)
Installation part (optional) PV Module Frame Plate/T-shaped Bolt4
Input connector Staubli MC4
Input wire length 0.1 m (short input cable version)5
Output connector Staubli MC4
Output wire length 0.1 m (+), 5.1 m (–) (short input cable version)5
Operating temperature / humidity range –40 °C to +85 °C6 / 0%–100% RH
Degree of protection IP68
Compatible Inverter SUN2000-8/10/12/15/17/20KTL-M2
SUN2000-30/36/40KTL-M3
SUN2000-12/15/17/20/23/25KTL-M5
SUN2000-50KTL-M3
String configuration (Full Optimizer Configuration)7 / 8 / 9
* MERC-1100/1300W-P
support full
optimizer
configuration only
SUN2000-8~20KTL-M2 SUN2000-12~25KTL-M5 SUN2000-30~40KTL-M3 SUN2000-50KTL-M3
Minimum optimizers per string 8 8 8 8
Maximum optimizers per string 25 25 25 20
Maximum DC power per string
20,000 W 20,000 W 20,000 W 20,000 W

*1 The maximum power of PV module at STC shall NOT exceed the “Rated input DC power” of MERC -1100/1300W-P. PV Modules with up to +5% power tolerance are allowed

*2 Any power optimizer, which is connected to an operating inverter in a PV string, will be bypassed when it fails.

*3 When the MERC -1100/1300W-P is disconnected from inverter or when the inverter is off, its output voltage will be 1 V.

*4 It is for PV module frame/extruded aluminum profile racking system installation.

*5 Pay attention to PV module wire length. To match PV modules with a split junction box and short output wire, the long-input-cable version (input wire: 1.3 m(+/-); output wire 0.1m(+)/2.9m (-) of MERC -1100/1300W-P is available upon request.

*6 When the operating temperature of the MERC -1100/1300W-P reaches 70 ℃ to 85 ℃, it may shut down due to over-temperature protection and report an over-temperature alarm. After the temperature decreases, it can automatically resume working without any damage.

*7 Each PV module under the same inverter must be equipped with a MERC -1100/1300W-P.

*8 SUN2000-450W-P2/600W-P and MERC -1100/1300W-P can NOT be used in mixture under the same Smart Energy/PV controller.

*9 It is recommended that strings under the same inverter have an equal capacity. If it is not feasible, the capacity difference between strings under the same inverter must not exceed 2 kW. Otherwise, the energy yield will be reduced.