HUAWEI SmartGuard

HUAWEI SmartGuard

HUAWEI SmartGuard
HUAWEI SmartGuard
HUAWEI SmartGuard

HUAWEI SmartGuard-63A-TO/AUTO

Technical Specification SmartGuard-63A-T0 SmartGuard-63A-AUT0
General Data specs-icon
Dimensions (W x H x D) 600 mm × 170 mm × 490 mm
Weight (not including mounting plate ) 17 kg
Performance specs-icon
AC voltage (nominal) 380 / 400 / 415 V, 220 / 230 / 240 V, L1 / L2 / L3 / N+PE
Max. current (from / to grid) 63 A
Max. current (from / to inverter) 60 A
Max. current (to backup load) 63 A
Max. current (to non-backupLoad)1 63 A
Low-voltage ride-through Supported
Switchover time ≤ 20 ms (MAP0), ≤ 100 ms (M1/MB0)2
Bypass operation mode Manual
DG mode Remote control
Interface specs-icon
Power output 9.5 ~ 13.2 V @ 100 mA, ≤ 3 m
LAN 10 / 100 Mbps, ≤ 100 m
WAN 10 / 100 Mbps, ≤ 100 m
WLAN AP Mode, 802.11b/g/n (2.4 GHz ~ 2.4835 GHz)
RS485 9600 / 19200 / 115200bps,× 2, ≤ 50 m
Digital input ×2, ≤ 20 m; Avtive port3
Digital output ×2, ≤ 20 m
DG do port Passive Port, 1-100 mA ≤ 24 V
ATS Need prepare the ATS, which supports automatic control and automatic switch-in and reset.
Measurement Range specs-icon
Current range ≤ 63 A
Energy accuracy ± 1%
Device Management specs-icon
Smart energy controllers up to 3
Smart chargers up to 2
Heat pump up to 14
Shelly device up to 20
Environment specs-icon
Cooling Natural Convection
Relative humidity range 5% ~ 95% RH (non condensing)
Max. operating altitude 4000 m (derating over 2000 m)
Degree of protection IP55
Operating temperature range -25 °C ~ 50 °C5
Compatible Device specs-icon
Smart energy controller Max. 3 inverters supported in parallel connection (MAP0)
Max. 1 inverter supported (M1/MB0)
Smart charger SCharger-7KS / 22KT-S0
Heat pump SG-ready
Shelly device Shelly Plus Plug S, Shelly Plus 2PM, Shelly Pro 2PM6

*1 The sum of the output current of the backup port and the non-backup port could not be more than 63 A.

*2 Seamless switching is disabled by default and needs to be manually enabled.

*3 The position feedback signal must be a passive port that works with an external circuit and can work at a current of less than or equal to 0.7 mA@12 V. The low impedance of the circuit for the position feedback signal is less than or equal to 100 ohms.

*4 1 SG-ready Heat Pump can be connected directly. Others can be connected via shelly devices.

*5 On-grid Mode: -25 ~ 30 °C, no derating; 30~50 °C, linear derating from 63 A to 43 A;
Off-grid Mode: -25 ~ 40 °C, no derating; 40 ~ 50 °C, linear derating from 60 A to 50 A.

*6 The supported firmware version of shelly devices can be found in user manual.

Disclaimer: the preceding values are measured by an internal laboratory of Huawei in a specific environment. The actual values may vary with products, software versions, usage conditions, and environmental factors.