Smart PV Controller

SUN2000-150K-MG0

Accessories

Smart PV Controller

Technical Specification SUN2000-150K-MG0
Efficiency specs-icon
Max. efficiency 98.6% @400V, 98.8% @480V
European efficiency 98.4%
Input specs-icon
Max. Input Voltage1 1,100 V
Max. Current per MPPT 48 A
Max. Current per Input 23 A
Max. Short Circuit Current per MPPT 66 A
Start Voltage 200 V
MPPT Operating Voltage Range2 200 V ~ 1,000 V
Number of MPP trackers 7
Max. input number per MPP tracker 3
Output specs-icon
Nominal AC Active Power 150,000 W
Max. AC Apparent Power 165,000 VA
Max. AC Active Power (cosφ=1) 165,000 W
Nominal Output Voltage 380 V/400 V/480 Vac
Rated AC Grid Frequency 50 Hz / 60 Hz
Nominal Output Current 227.9 A @380 V, 216.5 A @400 V, 180.4 A @480 Vac
Max. Output Current 253.2 A @380 V, 240.5 A @400 V, 200.5 A @480 Vac
Adjustable Power Factor Range 0.8 leading... 0.8 lagging
Alternating current THDi <1%
Protection specs-icon
Anti-islanding Protection Yes
AC Overcurrent Protection Yes
DC Reverse-polarity Protection Yes
PV-array String Fault Monitoring Yes
DC Surge Arrester Type II
AC Surge Arrester Type II
DC Insulation Resistance Detection Yes
Residual Current Monitoring Unit Yes
Smart String Level Disconnector Yes
Arc Fault Protection Yes
Terminal Temperature Detection Yes
PID Recovery Yes
PV Ground-Fault Protection Yes
Communication specs-icon
Display LED indicators; WLAN adaptor + FusionSolar APP
RS485 Yes
USB Yes
Smart Dongle-4G Smart Dongle – 4G / WLAN (Optional)
Monitoring BUS (MBUS) Yes (isolation transformer required)
General Data specs-icon
Dimensions (W x H x D) 1,000 x 710 x 395 mm
Weight (with mounting plate) 102 kg
Operating Temperature Range -25°C ~ 60°C
Cooling Method Smart Air Cooling
Max. Operating Altitude 4,000 m (13,123 ft.)
Relative Humidity 0 ~ 100%
DC Connector Amphenol HH4
AC Connector Waterproof Connector + OT/DT Terminal
Protection Degree IP66
Topology Transformerless
Standard Compliance (more available upon request) specs-icon
Certificate EN 62109-1/-2, IEC 62109-1/-2, IEC 62116, IEC 61727, IEC 60068, IEC 61683
Grid Connection Standards VDE-AR-N4105, EN 50549-1, EN 50549-2, RD 661, RD 1699, C10/11

* 1 The maximum input voltage is the upper limit of the DC voltage. Any higher input DC voltage would probably damage inverter.

* 2 Any DC input voltage beyond the operating voltage range may result in inverter improper operating.