Smart Module Controller

SUN2000-600W-P

Smart Module Controller
Smart Module Controller
Smart Module Controller
Smart Module Controller
Smart Module Controller
Smart Module Controller

Smart Module Controller

Technical Specification SUN2000-450W-P2 SUN2000-600W-P
Input specs-icon
Rated input DC power1 450 W 600 W
Absolute max. input voltage 80 V
MPPT operating voltage range 10 ~ 80 V
Max. short-circuit current (Isc) 14.5 A
Input Overcurrunt Protection 15 A
Max. efficiency 99.5%
Weighted efficiency 99.0%
Overvoltage category II
Output specs-icon
Max. output voltage 80 V
Max. output current 15 A
Output bypass2 Yes
Output voltage during standby3 0 V
Output impedance during standby 1 kΩ ± 10%
Communication specs-icon
Communication protocol MBUS
Standards Compliance specs-icon
Safety IEC62109-1 (class II safety)
RoHS Yes
Fire Safety VDE-AR-E 2100-712:2018-12
General Specifications specs-icon
Dimensions (W x H x D) 75 mm x 140 mm x 28 mm (3.0 in. x 5.5 in. x 1.1 in.)
Weight (including cables) 0.6 kg (1.3 lb.)
Installation part (optional) Frame mounting bracket / T-shaped bolt4
Input connector Staubli MC4
Input wire length 0.15 m (0.49 ft.)
Output connector Staubli MC4
Output wire length 1.3 m (4.3 ft.)
Operating temperature / humidity range -–40 °C to +85 °C 5 / 0% - 100%
IP rating IP68
Compatible inverters SUN2000-12K/15K/17K/20K/25K-MB0, SUN2000-8K/10K-LC0,
SUN2000-2/3/3.68/4/4.6/5/6KTL-L1, SUN2000-3/4/5/6/8/10KTL-M1,
SUN2000-12/15/17/20/25KTL-M5
PV System Design6 SUN2000-
2~6KTL-L1
SUN2000-
8K/10K-LC0
SUN2000-
3~10KTL-M1
SUN2000-
12~25KTL-M5
SUN2000-
12K/15K/17K/
20K/25K-MB0
Min. string length (power optimizers) 4 4 6 6 6
Max. string length (power optimizers) 25 25 35 35 35
Max. DC power per string 6,000 W 6,000 W 10,000 W 12,000 W 12,000 W

*1 The maximum power of PV module at STC shall NOT exceed the “Rated Input DC Power” of the power optimizer. PV modules with up to +5% power tolerance are allowed.

*2 Any power optimizer, which is connected to an operating inverter in a PV string, will be bypassed when it fails.

*3 Once the power optimizer stops working, its output voltage is reduced to 0 V.

*4 It is for PV module frame/extruded aluminum profile racking system installation.

*5 When the operating temperature of the SUN2000-450W-P2/600W-P reaches 70 °C to 85 °C, it may shut down due to over-temperature protection and report an over-temperature alarm. After the temperature decreases, it can automatically resume working without causing any damage.

*6 SUN2000-450W-P2/600W-P and MERC-1100/1300W-P can NOT be used in mixture under the same Smart Energy/PV Controller.



Disclaimer: the preceding values are measured by an internal laboratory of Huawei in a specific environment. The actual values may vary with products, software versions, usage conditions, and environmental factors.